Hello,
this time i share with you, how i repaired 2 kw dimmer. This dimmer used for dimming 230V AC LED A60 bulbs. Circuit is very simple.
First i checked defective unit attached with incandescent light. Result is no dimmer function & only light on with fully bright.
so i removed backside cover & trace the circuit. After, i checked triac of this circuit. Checked with multi meter i saw SOURCE & DRAIN show as short circuit. So i decide to change the new triac.
Existing triac was BTA21. But i cannot found this in our local market. So i choose BTA41 to replaced with this.
Triac was reverted to the heat sink, so i had to cut this revert to remove the triac & solder it. After done this, i replaced with new one.
Finally i checked again with incandescent light, now it is dimming well. Here is the schematic of this dimmer.
thanks for viewing my experience. Hope this may be impotent yo you.
so i removed backside cover & trace the circuit. After, i checked triac of this circuit. Checked with multi meter i saw SOURCE & DRAIN show as short circuit. So i decide to change the new triac.
Existing triac was BTA21. But i cannot found this in our local market. So i choose BTA41 to replaced with this.
Triac was reverted to the heat sink, so i had to cut this revert to remove the triac & solder it. After done this, i replaced with new one.
Finally i checked again with incandescent light, now it is dimming well. Here is the schematic of this dimmer.
thanks for viewing my experience. Hope this may be impotent yo you.